OPERATION
GROUNDING THE GENERATOR
The National Electrical Code requires that the frame and
external electrically conductive parts of this generator be
properly connected to an approved earth ground. Local
electrical codes may also require proper grounding of
the unit. For that purpose, a GROUNDING FASTENER
is provided on the generator end (Figure 7).
Generally, connecting a No. 12 AWG (American Wire
Gauge) stranded copper wire to the grounding fastener
and to an earth-driven copper or brass grounding rod
(electrode) provides adequate protection against elec-
trical shock. Be careful to keep the grounding wire
attached after connecting the stranded copper wire.
However, local codes may vary widely.
Properly grounding the generator helps prevent electrical
shock if a ground fault condition exists in the generator
or in connected electrical devices, especially when the
unit is equipped with a wheel kit. Proper grounding also
helps dissipate static electricity, which often builds up in
ungrounded devices.
Fig. 7
WARNING:
Consult with a local electrician for grounding
requirements in your area.
Grounding
Fastener